2.5MVA 3-Phase Dry Type Unitized Substation
Price 3700000 INR/ Piece
2.5MVA 3-Phase Dry Type Unitized Substation Specification
- Rated Voltage
- 11kV/0.415kV
- Low Voltage
- 415V
- Operating Temperature
- -10C to +50C
- Capacity
- 2500kVA
- Voltage Booster Type
- Step Down
- Dimension (L*W*H)
- 3500mm x 1800mm x 2300mm
- High Voltage
- Up to 11kV
- Standard
- IEC 60076, IS 1180, IS 2026
- Coil Material
- Copper/Aluminum
- Load Loss
- Low (as per IEC60076/IS1180)
- Cooling Type
- AN/AF (Air Natural/Air Forced)
- Product Type
- Unitized Substation
- Material
- composite board and steel
- Output
- 2.5 MVA
- Frequency (MHz)
- 50-60 Hertz (HZ)
- Efficiency
- 98-99%
- Phase
- Three Phase
- Usage
- Industrial
- Coil Structure
- Dry Type
- Coil Number
- Three
- Power Scope
- 2500kVA (2.5MVA)
- Weight
- Approx. 8-10 Tons
- Connection Type
- Copper Busbar
- Noise Level
- <65 dB at 1 meter
- Maximum Altitude
- Up to 1000m Above Sea Level
- Ambient Humidity
- 95% RH (Non Condensing)
- Enclosure Protection
- IP54/IP55
- Maintenance
- Minimal, Easy Access Design
- Fire & Smoke Resistance
- High, Self-Extinguishing Material
- Insulation Class
- Class F/H
- Secondary Side Protection
- MCB/MCCB/Air Circuit Breaker
- Tap Changer
- On-load/Off-load Tap Changer (OLTC/OLTC)
- Cooling Fan
- Optional
- Installation
- Outdoor/Indoor
- Short Circuit Withstand
- As per IEC
- Monitoring/Protection
- Digital Metering & Protection Relays
- Paint Finish
- Epoxy Powder Coated
2.5MVA 3-Phase Dry Type Unitized Substation Trade Information
- Minimum Order Quantity
- 1 Piece
- Supply Ability
- 10 Pieces Per Month
- Delivery Time
- 7 Days
About 2.5MVA 3-Phase Dry Type Unitized Substation
Commercial Application & Advanced Features
The 2.5MVA 3-Phase Dry Type Unitized Substation is tailored for commercial zones, offices, manufacturing units, and data centers. Optimum secondary side protection, low load loss, and noise level below 65 dB assure smooth, uninterrupted operations. Majestic construction ensures minimal maintenance, while monitoring and protection relays provide dependable oversight. Suitable for both indoor and outdoor installations, its reduced footprint and matchless versatility make it ideal for demanding environments.
Packaging, Markets & Timely Delivery
Packaging details emphasize reinforced, secure transport services suitable for domestic and global clients. Main export markets span India, Middle East, Africa, and Southeast Asia. Quick dispatch and efficient handover are part of the process, ensuring products arrive undamaged and installation-ready. Packaging uses sturdy materials; each unit packed for optimum safety during transit. Delivery times generally range from 2 to 3 weeks, contingent on destination and transport mode.
FAQs of 2.5MVA 3-Phase Dry Type Unitized Substation:
Q: How is the 2.5MVA 3-Phase Dry Type Unitized Substation protected against fire and smoke?
A: This substation features high fire and smoke resistance, utilizing self-extinguishing materials to ensure safety and compliance during hazardous incidents.Q: What are the main application areas of this elite unitized substation?
A: It is primarily used in industrial facilities, commercial complexes, office buildings, data centers, and manufacturing plants.Q: When can I expect handover after placing an order for export?
A: Typically, the unit is ready for handover within 2 to 3 weeks of order confirmation, depending on client location and chosen transport services.Q: Where can the substation be installed for optimum performance?
A: The substation is designed for both outdoor and indoor installation, accommodating versatile layouts and environmental conditions.Q: How does the digital monitoring system benefit daily operations?
A: Digital metering and protection relays provide real-time system data, enabling efficient control, diagnostics, and early detection of faults for uninterrupted service.Q: What is the process for installation and maintenance?
A: Installation involves site preparation and connection of copper busbars; maintenance is minimal due to easy access design and durable materials.Q: What are the advantages of the reduced noise level feature?
A: A noise level below 65 dB at 1 meter supports quiet operations, essential for use near residential or office zones.
Price:
- 50
- 100
- 200
- 250
- 500
- 1000+
More Products in Compact Secondary Substation Category
500kVA 3 Phase Oil Cooled Compact Substation (CSS)
Price 600000 INR / Piece
Minimum Order Quantity : 1 Piece
Material : Mild Steel
Product Type : Other, Oil Cooled Compact Substation
Phase : Three Phase
Usage : Industrial
VCB Panel
Price 250000 INR / Piece
Minimum Order Quantity : 1 Piece
Material : Mild Steel
Product Type : Other, VCB Panel
Phase : Three Phase
Usage : Industrial
33KV Indoor SF6 Switchgear Panel
Price 800000 INR / Piece
Minimum Order Quantity : 1 Piece
Material : Mild Steel
Product Type : Other, Switchgear Panel
Phase : Three Phase
Usage : Industrial
APFC Capacitor Panel
Price 200000 INR / Piece
Minimum Order Quantity : 1 Piece
Material : Mild Steel
Product Type : Other, Apfc Panel
Phase : Three Phase
Usage : Industrial
![]() |
BVM TECHNOLOGIES PVT. LTD.
All Rights Reserved.(Terms of Use) Developed and Managed by Infocom Network Private Limited. |
English
Spanish
French
German
Italian
Chinese (Simplified)
Japanese
Korean
Arabic
Portuguese






Send Inquiry